Optimizing performance of Kona Gateways

Optimizing performance of Kona Gateways

As we have made improvements on Kona Gateways and TEK NS recently, we strongly recommend our customers to update following configuration settings on Kona Gateways in order to maximize performance.

 

  • As MQTT offers a more reliable connection between gateways and network server than UDP, we recommend making following changes:

 

  1. In config.json file located in /etc/default/ directory, set server_address to 127.0.0.1 instead of NS URL.

 

  1. In mqtt-bridge.conf file located in /etc/default/ directory,  set ns_host to lorawan-ns-na.tektelic.com or lorawan-ns-eu.tektelic.com.

 

When making changes to multiple gateways in the same group, you can use the Group Configuration option as shown in screenshots below of Gateway Groups tab.



 


After making above changes, power cycle the gateway manually or use Reboot option found under Commands tab from TEK NS.




    • Related Articles

    • Kona Gateways BSP Upgrade using KonaFT

      This document describes the procedure required for upgrading the BSP (firmware) on Kona Enterprise/Micro/Macro/Mega Gateways using KonaFT. Kindly note that this document DOES NOT apply to the Kona Pico Gateway.
    • Kona Gateways BSP Upgrade using CLI

      This document describes the procedure to BSP upgrade Kona Gateways (Enterprise/Micro/Macro/Mega) using CLI. It assumes you are familiar with operating and navigating through Linux environments and file transfer programs. Kindly note that this article ...
    • Kona Gateways FAQ (Applicable to Kona Micro/Macro/Mega)

      #1 How does network monitoring mechanism work in Kona Gateways? Kona Gateways supports Ethernet and Cellular interfaces for network connectivity. By default, Ethernet is primary interface and Cellular is fallback interface. Users can change ...
    • Enabling Class B devices on Kona Gateways

      Enabling Class-B Beacon Frames: The Mega/Macro/Enterprise gateways can be configured to transmit class-B beacon frames. To do this, modify the following entries in the gateway_conf object in the /etc/default/config.json file:             "//beacon": ...
    • Kona Gateways BSP Upgrade using Tektelic OAM Server

      This article contains the procedure to upgrade the BSP (firmware) of Kona Enterprise/Micro/Macro/Mega gateways using Tektelic OAM Server. The procedure can be found in the attachments. Kindly note that this article does not apply to the Kona Pico ...